RegistRead

For Diaphragm Gas Meters and Electromechanical Electric Meters

For diaphragm gas meters and electromechanical electric meters, RegistRead provides the most options for AMI and submetering. Digital Form A output devices fit on the drive dial or reading dials of meters. They are protected under the index cover, and can be supplied pre-installed on meter indexes for ease of installation and reliability.

Options include 1, 2, 0r 10/revolution resolutions, dual outputs, power saving electronics, and custom wire lengths. Safe for hazardous environments, they are approved by Canadian, New York, and California authorities.

Output: Form A, Digital dry contact; optional “PS4” FET transistor output for power saving

Resolution: 1, 2, or 10 pulses/rev of drive dial or reading dial.

Maximum Pulse Rate: Based on meter speed; approx 3 seconds/pulse shortest output with 2/rev on drive dial

Duty Cycle: 60% on, 40% off, ± 6%

Temperature: Operational from -40° to +240°F

Options for All Products: dual, separate outputs; FET type electronics; custom wire lead lengths; wire tamper sense

 

MANUFACTURER  SIZE, CFH

INDEX TYPE

 

CR: Circular read

DR: Direct Read

RIO Tronics MODEL

RESOLUTION

 

cubic foot; cubic meter available

Elster/American Meter 175-250-425-630 CR, DR

RD AMRC – 2P

 

RD AMRC-1P

1

 

2

800 through 5000; Turbines CR

RD AMRC – 2P

 

RD AMRC – 1P

2.5, 5, 50

 

5, 10, 100

 

800 through 5000; Turbines DR

RD AMRC-2P-SS

 

RD AMRC-1P-SS

2.5, 5, 50

 

 

5, 10, 100

Sensus 175through 415 CR

PPIN2 – 2P

 

RD 5053-2P

RD 5053-1P

1

 

1

2

175 through 415 DR

RD 43-2P

 

RD 43 – 1P

1

 

2

750-10000, + Turbo Meter CR only

RD 41-2P,

 

RD 41 – 1P

requires MC818 cover

2.5, 5, 50

 

5, 10, 100

Actaris/Itron 250-400 CR, DR

PPSA2-2P

 

RD SPRG – 2P

RD SPRG – 1P

1

 

1

2

675-800-1000 CR, DR

RD SPRG-2P

 

RD SPRG – 1P

5

 

10

RegistRead: “DK” Type Device

Pre-installed on meter index-replace meter index register with RIOTronics’-”DK” type index, exit wire through cover with hole drilled 7/32” for provided grommet. Test output with multimeter at 100 ohms resistance on, infinite ohms off.

 

For RegistRead components not provided on meter index, see instructions.

Wiring Diagram

RIO Tronics has a distributor network across the US and Canada, and can refer them via email or phone. Please send us a message using the form below or call us at 303-733-2600 for more information.

Call to Order
303-773-2600

For additional product details, distributor, or pricing information,
please email in the section at the right, or phone at the number above.

We can also answer questions about delivery times and product features and options.

For information on availability of outputs for your meters, please send photos of the meters, with close up photos of the dial sections, via the form at the right on this page.

Send Us a Message

  • Accepted file types: jpg, gif, png, pdf, Max. file size: 512 MB.
    Upload image of meter ( jpg, gif, png, pdf)
  • This field is for validation purposes and should be left unchanged.